- Auto Motor[3]
- Car Alternator[1]
- Circuit Breakers[10]
- Connectors[10]
- Contactors[5]
- Electrical Plugs & Sockets[7]
- Fuses[2]
- Other Electrical Equipment[8]
- Power Distribution Equipment[1]
- Inverters & Converters[5]
- Switching Power Supply[1]
- Voltage Regulators/Stabilizers[8]
- Relays[10]
- Other Switches[3]
- Push Button Switches[9]
- Rotary Switches[4]
- Time Switches[4]
- Transformers[1]
- Power Cords & Extension Cords[1]
- Capacitors[1]
- Counters[1]
- Energy Meters[5]
- Power Meters[2]
- Timers[4]
- Seals[10]
- Carbon[2]
- Lightning Rod[1]
- Contact Person : Mr. huang zan
- Company Name : Manhua Electric Co., Ltd.
- Tel : 0086-577-62773 883
- Fax : 0086-577-62766508
- Address : Zhejiang,Yueqing,No.888,chezhan road,Liushi Town,
- Country/Region : China
- Zip : 325604
Related Product Searches:Control protective switching devices,High Quality,Control protective switching devices,protective switch,CPS
Main technical data:1) Two outline dimensions (C and D frame size): 3-pole and 4-pole2) Current ratings: C Frame: 12A, 16A, 18A, 32A, 45A; D Frame: 45A, 63 A,100A,125A3) setting current: 0.16A~125A4) Short-circuit break capacity: a) 35kA for type C (economic) b) 50kA for type Y (standard) c) 80kA for type H (high capacity)5) Opening time under prospective short-circuit current is 2 ~ 3ms, at current limiting of 0.2 and below.
Functions:
MKB0 adopts modularized single structure and integrates main function of traditional circuit breaker ,fuse, contactor, overload (or over current, open phase) relay, starter and isolator, it owns remote automatic control and local direct manual control function as well panel indication and electrical signal alarm function, it also has coordinated time-current protection characteristic (three sections protection characteristics of inverse time delay, definite time delay and instantaneous), shown as fig. 4. Functional module and accessory can be selected and used to realize control and protection for general (infrequent start) motor load, motor load of infrequent start and distribution circuit load according to requirement.
Inm frame current | Rated current of main body In(A) | Rated current of intelligent controller le(A) | Current setting of short delay triiping Ir2(A) | Current setting of long delay triiping Ir1(A) | Controllable capacity at 380V(KW) | Usage category |
45 | 1216183245 | 0.4 | 0.48-4.8 | 0.16-0.4 | 0.05-0.12 | AC-42AC-43AC-44 |
1 | 1.2-12 | 0.4-1 | 0.12-0.33 | |||
2.5 | 3-30 | 1-2.5 | 0.33-1 | |||
4 | 4.8-48 | 1.6-4 | 0.33-1.6 | |||
6.3 | 7.5-75 | 2.5-6.3 | 1-2.5 | |||
12 | 14.4-144 | 4.8-12 | 2.2-5.5 | |||
16 | 19.2-192 | 6.4-16 | 2.5-7.5 | |||
18 | 21.6-216 | 7.2-18 | 3.0-7.5 | |||
25 | 30-300 | 10-25 | 5.5-11 | |||
32 | 38.4-384 | 12.8-32 | 5.5-15 | |||
40 | 48-480 | 16-40 | 7.5-18.5 | |||
45 | 54-540 | 18-45 | 7.5-22 | |||
6.3 | 7.5-75 | 2.5-6.3 | 1-2.5 | |||
125 | 161832455063100125 | 12 | 14.4-144 | 4.8-12 | 2.2-5.5 | |
16 | 19.2-192 | 6.4-16 | 2.5-7.5 | |||
18 | 21.6-216 | 7.2-18 | 3.0-7.5 | |||
25 | 30-300 | 10-25 | 5.5-11 | |||
32 | 38.4-384 | 12.8-32 | 5.5-15 | |||
40 | 48-480 | 16-40 | 7.5-8.5 | |||
45 | 54-540 | 18-45 | 7.5-22 | |||
50 | 60-600 | 20-50 | 7.5-22 | |||
63 | 75.6-756 | 25.2-63 | 11-30 | |||
80 | 96-960 | 32-80 | 15-37 | |||
100 | 120-1200 | 40-100 | 18.5-45 | |||
125 | 150-1500 | 50-125 | 22-55 |
Control protective switching devices